Ionizing Bars

 

 

 

 

 Ionzing Air Bars Charged Plate decay times for two distances: 300mm and 600mm

Temperature During Test: 24 Deg. C.                       Humidity DuringTest=40%

               
Item Bar Length(MM) Air Pressure        (Kg/cm^2) Decay time of the 6"x6" charged plate from (1000-100V) Remarks
Distance (MM) Decay Time +(s) Decay Time   -(s) Ion Balance(v)
1 300 5 300 1,2 1,1 16 There is one air inlet.  ∮8mm PU quick connect socket.
600 1,7 1,9 13
2 500 5 300 1,3 1,2 13
600 2 2,2 20
3 600 5 300 1,1 1,1 10
600 1,6 1,6 3
4 800 5 300 2,1 2,1 8
600 2,6 2,6 4
5 1400 5 300 1,3 1,4 16 There are two air inlets。∮8mm PU quick connect sockets.
600 1,9 2 9
6 2500 5 300 1,7 1,5 9 There are three air inlets。∮8mm PU quick connect sockets.
600 2,6 2,1 2
               

Note:

1. The decay time increases with increasing bar lengths. 

2. When using one power supply for 2 ionzing bars at the same time, the decay times for bothh bars are same as in the table above for the bar lengths of the bars not exceeding  2500mm.

3. The connection power cord from power supply to the ionizing air bar must be below 3m in length.

 

 

 

 

ALB - 50- - SET SPECIFICATION
  ALB - 60- - SET SPECIFICATION
  ALB - 80- SET   SPECIFICATION
  ALB - 100- SET SPECIFICATION
  ALB - 120- SET  SPECIFICATION
  ALB - 150- SET SPECIFICATION

 

 

 

   ALB - 60- - BO  SPECIFICATION
    ALB - 80- - BO   SPECIFICATION
   ALB - 100- - BO  SPECIFICATION
     ALB - 120- - BO  SPECIFICATION
     ALB - 150- - BO  SPECIFICATION

 

 




Quick Search

American Distribution

United States of America,
Canada and Mexico: 
BOMIR INC. (Master Distributor)
E-mail: bomir@bomir.com
Tel: (570)842-4725
Fax: (570)842-4290

Disclaimer

Bokar International is committed to continuing development of new products and improvements to existing products. Specifications are subject to change without notice.

2012 Design by GraphicSite STUDIO. All rights reserver.